Ada Bathroom Stall
Doors in bathrooms should be facing the wc in a diagonal direction and located on the side walls.
Ada bathroom stall. If the depth of a standard toilet stall is increased at least 3 in 75 mm then a floor mounted water closet may be used. Figure 30 a standard stall. Bathtubs hot tubs. The ada standards require that unisex toilet rooms where provided have privacy latches and contain at most one lavatory one water closet and one urinal or a second water closet 213 2 1.
Floor toilet stalls should be at least 59 inch wide while wall mounted should be at least 56 inch wide. Toilets must be located within 16 18 inches from the centerline of the wall meihls says. Or for answers to specific questions call the toll free ada information line at 800 514 0301 voice or 800 514 0383 tty. Ada standards for accessible design can be downloaded from www ada.
Horizontal grab bars must be installed behind the toilet and on the nearest wall or partition whichever is closer. More or less than that makes maneuvering difficult. The requirements of the actual toilet grab bars and toilet paper dispenser remain essentially the same. However the enclosure walls must meet certain dimensional requirements.
Standard toilet stalls with a minimum depth of 56 in 1420 mm see figure here under shall have wall mounted water closets. The centerline of the water closet is 18 inches 455 mm from the side wall. All standard stalls must be at least 60 inches wide. The location of the door is in front of the clear space and diagonal to the water closet with a maximum stile width of 4 inches 100 mm.
Arrangements shown for standard toilet stalls may be reversed to allow either a left or right hand approach. The center line of the wc should be at least 18 inch away from the side walls. For more information for information about the ada including the revised 2010 ada regulations please visit the department s website www ada gov. The minimum width of the stall is 60 inches 1525 mm.
These requirements apply to all government state local parks recreational centers and commercial businesses for new and altered construction sites. The americans with disabilities act ada has established minimum requirements for public restrooms and commercial bathrooms. Ada bathroom layout guidelines are designed to protect people with disabilities and ensure that they have appropriate space in the public restrooms. In a public bathroom that has stalls at least one must be a standard ada stall.
Toilet seat heights must be 17 to 19 inches above the finished floor. Toilet flush levers are also supposed to be installed on the open side of the stall so that the user doesn t have to reach over the toilet meihls adds. Accessible toilet stalls or compartments must have a minimum width of 60 inches and sufficient space to accommodate a wheelchair to the sides of the toilet or in front of it. Ada standards for accessible design can be downloaded from www ada.
Or for answers to. Medical care and long term care facilities 223 1 805 4.